Equipment / TAIET
MPFU HIFU Facial Probe Series for Multi-Depth Layered Treatment
No reviews yetKey attributes
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
Similar products
Key attributes
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The TAIET MPFU system offers a dedicated facial probe series spanning multiple tissue depths for comprehensive layered treatment. From superficial epidermal engagement through to the SMAS fascial layer, each probe in the series targets specific structural levels of facial anatomy. This multi-depth approach allows practitioners to address tone, texture, line reduction, and foundational support within a single platform configuration. The ultramicro pulse ultrasonic technology delivers bidirectional energy switching with microsecond transmission for precise thermal condensation point formation at each designated layer. Combined with the flat handpiece point and MP modes, the probe series enables customized protocols based on individual skin condition, age-related changes, and treatment objectives across the full facial architecture.
| Parameter | Specification |
|---|---|
| Model | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |