Equipment / L10
L10 CO2 Fractional Vaginal Laser with Radial Emission Cannula
No reviews yetKey attributes
- Laser Wavelength
- 9.3–10.6 μm
- Far-Infrared Wavelength
- 10.6 μm
- Laser Power
- 60 W
- Operating Frequency
- 0–20 KHz
- RF Frequency
- 20 KHz
- Total Power
- 350 W
Similar products
Key attributes
| Laser Wavelength | 9.3–10.6 μm |
|---|---|
| Far-Infrared Wavelength | 10.6 μm |
| Laser Power | 60 W |
| Operating Frequency | 0–20 KHz |
| RF Frequency | 20 KHz |
| Total Power | 350 W |
| Spot Size | 2.5 ± 0.2 mm |
| Power Supply | 110V–230V |
| Product Size | 616 × 342 × 175 mm |
| Display Screen | 7-inch Color Touch Screen |
| Shell Material | Sheet Metal + Plastic |
| Color | Black + Dark Gray |
| Output Mode | TEM00 |
| Cooling System | Air Cooling + Water Cooling |
| Maximum Output Power | 30 W |
| CO2 Laser Wavelength | 10.6 μm |
| Power Cable Specification | 220V, 10A single-phase AC |
| Water Replacement Interval | once a month |
| Water Type | purified water or distilled water |
| Distance Adjustment Range | 0.1-2.6 nm |
| Duration Adjustment Range | 0.1-10 ms |
| OFF Time Adjustment Range | 1-1000 ms |
| On Time Adjustment Range | 1-1000 ms |
| Overlap Adjustment Range | 1-20th |
| Point Adjustment Range | 4-100 ms |
| Power Adjustment Range | 1-60 W |
| Pulse Width Adjustment Range | 5.0-995.0 ms |
| Rcan Line Number Adjustment Range | 0.1-10.0 J/cm² |
| Repeat Adjustment Range | 1-1000 ms |
| Row Adjustment Range | 1-10 |
| Shape Adjustment Range | 4.0x4.0 to 12.0x12.0 mm |
| Size Fixed Value | 10.0 mm |
| Working Mode Options | Single, Continuous, Pulse |
| Scan Mode Options | Sequential Mode, Random Mode, Split Mode |
| Temperature Range | 50-70 °C |
| Wavelength | 10,600 nm |
| Cannula Withdrawal Distance | 0.5 cm |
| Treatment Distance | approximately 5 CM |
| Internal Treatment Count | three |
| Articulated Arm Count | 6 |
| Screen Size | 7-inch |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The L10 CO2 fractional vaginal laser delivers internal treatments through a 360-degree radial emission cannula designed for comprehensive vaginal wall coverage. The cannula withdraws at fixed intervals to ensure sequential, overlapping treatment zones along the full length of the vaginal canal. Operators complete three full passes per session, with the device automatically supporting controlled repositioning for consistent energy delivery throughout the procedure. This approach integrates with the system's gynecological mode, which works alongside fractional, pulsed, and external vulvar settings on a single platform. The touchscreen interface allows direct switching between English and Chinese during setup, while the articulated arm with galvo head maintains flexible positioning across all treatment applications. A dual cooling configuration combining air and water systems supports sustained operation, with monthly distilled water replacement as part of routine maintenance. The unit connects to standard single-phase AC power and activates via footswitch, incorporating an emergency stop for immediate shutdown when needed.
| Parameter | Specification |
|---|---|
| Model | L10 |
| Laser Wavelength | 9.3–10.6 μm |
| Far-Infrared Wavelength | 10.6 μm |
| Laser Power | 60 W |
| Operating Frequency | 0–20 KHz |
| RF Frequency | 20 KHz |
| Total Power | 350 W |
| Spot Size | 2.5 ± 0.2 mm |
| Power Supply | 110V–230V |
| Product Size | 616 × 342 × 175 mm |
| Display Screen | 7-inch Color Touch Screen |
| Shell Material | Sheet Metal + Plastic |
| Color | Black + Dark Gray |
| Output Mode | TEM00 |
| Cooling System | Air Cooling + Water Cooling |
| Maximum Output Power | 30 W |
| CO2 Laser Wavelength | 10.6 μm |
| Power Cable Specification | 220V, 10A single-phase AC |
| Water Replacement Interval | once a month |
| Water Type | purified water or distilled water |
| Distance Adjustment Range | 0.1-2.6 nm |
| Duration Adjustment Range | 0.1-10 ms |
| OFF Time Adjustment Range | 1-1000 ms |
| On Time Adjustment Range | 1-1000 ms |
| Overlap Adjustment Range | 1-20th |
| Point Adjustment Range | 4-100 ms |
| Power Adjustment Range | 1-60 W |
| Pulse Width Adjustment Range | 5.0-995.0 ms |
| Rcan Line Number Adjustment Range | 0.1-10.0 J/cm² |
| Repeat Adjustment Range | 1-1000 ms |
| Row Adjustment Range | 1-10 |
| Shape Adjustment Range | 4.0x4.0 to 12.0x12.0 mm |
| Size Fixed Value | 10.0 mm |
| Working Mode Options | Single, Continuous, Pulse |
| Scan Mode Options | Sequential Mode, Random Mode, Split Mode |
| Temperature Range | 50-70 °C |
| Wavelength | 10,600 nm |
| Cannula Withdrawal Distance | 0.5 cm |
| Treatment Distance | approximately 5 CM |
| Internal Treatment Count | three |
| Articulated Arm Count | 6 |
| Screen Size | 7-inch |