Equipment / TAIET
MPFU HIFU System with Multi-Point Line Mode
No reviews yetKey attributes
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission mode
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
Similar products
Key attributes
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The TAIET MPFU HIFU system delivers multi-point line mode with four hundred seventeen points per shot, enabling rapid coverage across broad treatment zones. This configuration uses microsecond energy transmission with bidirectional switching between lateral linear acoustic pulse and ring acoustic wave modes. The flat handpiece supports seamless transitions between point and line combinations for customized layering across skin, fat, and fascial levels. Operators select normal or micropulse TCP thermal condensation modes through the same probe interface without hardware changes. The system achieves a two-point-five times speed improvement over conventional single-output systems, reducing cycle intervals while maintaining precise energy delivery. Pen-type and ring handpieces extend adaptability for detailed contouring and surface operations. MF2 five-point-five MHz eye-specific probe technology addresses delicate periorbital areas with dedicated patent-protected engineering.
| Parameter | Specification |
|---|---|
| Model | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |