Equipment / TAIET
Dual-Mode HIFU System with Lateral Linear and Ring Acoustic Wave Architecture
No reviews yetKey attributes
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
Similar products
Key attributes
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The TAIET system deploys lateral linear acoustic pulse and ring acoustic wave dual mode technology through a bidirectional energy switch, enabling seamless transition between point, line and surface treatment configurations. This MPFU ultramicro pulse ultrasonic architecture delivers microsecond energy transmission with smaller, denser gathering points than conventional systems for enhanced safety and comfort across full-layer applications from skin to superficial fascia, fat and muscle layers. The flat handpiece supports both point and MP modes for layered skin treatment, while the ring handpiece provides continuous annular operation through an ultra-booster pen-type circular design. Both handpieces share interchangeable probe interfaces that allow free mode switching without hardware changes, supporting customized protocols for facial contouring, submental refinement and body applications through coordinated thermal condensation point delivery in normal and micropulse modes.
| Parameter | Specification |
|---|---|
| Model | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |