MPFUマイクロパルスHIFU 熱凍結点重畳搭載
レビューはまだありません主な仕様
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
類似製品
主な仕様
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
レビュー
製品レビューはまだ公開されていません。
店舗レビューはまだ公開されていません。
サプライヤー
製品説明
The TAIET system introduces TCP Micropulse Mode with superposition of thermal freezing points, a configuration that distributes energy uniformly across target tissue layers rather than concentrating at isolated points. This approach extends the coverage area while maintaining the precision expected from MPFU technology, allowing practitioners to address broader zones in a single pass without sacrificing control over depth or intensity. The micropulse delivery works in concert with the standard TCP thermal condensation point method, giving clinics flexibility to alternate between concentrated and dispersed energy patterns based on treatment goals. Both modes operate through the same probe interface, eliminating hardware swaps during sessions. The bidirectional energy switch supports seamless transitions, reducing cycle intervals compared to conventional single-output systems. For facial applications, this dual-mode capability proves particularly valuable when treating areas requiring both structural lifting and surface refinement, such as the submental region or periorbital zone where tissue characteristics vary within millimeters.
| 項目 | 仕様 |
|---|---|
| モデル | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |