Equipment / TAIET
MPFU Ultramicro Pulse Ultrasonic System with Bidirectional Energy Switch
No reviews yetKey attributes
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
Similar products
Key attributes
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The TAIET MPFU system delivers microsecond energy transmission through a bidirectional energy switch, combining lateral linear acoustic pulse with ring acoustic wave modes in one platform. This dual-mode architecture allows seamless switching between point, line and surface treatment configurations for comprehensive facial and body applications. The flat handpiece supports both point and MP modes for layered skin treatment across multiple tissue levels, while the ring handpiece enables continuous circular energy delivery through an ultra-booster pen-type design. Both handpieces share interchangeable probe interfaces for flexible modality selection during sessions. The system incorporates TCP thermal condensation point technology in normal mode for collagen formation, alongside a micropulse mode that achieves superposition of thermal freezing points for broader energy distribution across target layers. Dedicated probe series cover facial depths from superficial to SMAS levels, with additional body probes operating at multiple frequencies for contouring applications. A specialized linear running probe addresses submental and body areas requiring extended treatment paths.
| Parameter | Specification |
|---|---|
| Model | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |