Equipment / TAIET
Micropulse Ultrasonic System with Two-Way Instantaneous Energy Switch
No reviews yetKey attributes
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission mode
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
Similar products
Key attributes
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The TAIET system employs MPFU ultramicro pulse ultrasonic technology with a bidirectional energy switch, enabling lateral linear acoustic pulse and ring acoustic wave dual modes in one platform. This design allows practitioners to move between point, line and surface combination treatments using flat and ring handpieces without changing the probe contact interface. The microsecond energy transmission mode delivers smaller, denser gathering points than conventional systems for uniform energy distribution across skin layers, superficial fascia, fat and muscle tissue levels. Thermal condensation point technology operates in both normal and micropulse modes, with the latter achieving superposition of thermal freezing points for intensive, extensive action on target regions. The pen-type circular ring handpiece with 8mm diameter enables infinite loop operation for surface coverage, while the MF2 eye-specific patent probe at 5.5MHz addresses delicate periorbital areas. Multi-point line mode and single point mode options support customized full-layer anti-aging protocols with comfortable patient experience and minimal recovery interruption.
| Parameter | Specification |
|---|---|
| Model | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |