Micropulse TCP HIFU System for Controlled Thermal Condensation
No reviews yetKey attributes
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission mode
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
Similar products
Key attributes
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The TAIET system deploys TCP Thermal Condensation Point technology in Micropulse Mode, delivering microsecond energy transmission through an ultramicro pulse ultrasonic platform. This configuration achieves superposition of thermal freezing points that uniformly and intensively act across target tissue layers. The micropulse approach enables tiny, precise energy distribution with more extensive coverage than conventional point-based delivery, supporting full-layer treatment from skin through superficial fascia and deeper structures with comfortable, efficient sessions that respect client downtime needs while maintaining epidermal integrity throughout the procedure. The same probe interface freely switches between modes, allowing practitioners to alternate micropulse TCP with normal mode TCP or point configurations without hardware changes during a single treatment flow. Ring handpiece operation integrates with the pen-type circular design for seamless surface coverage, while flat handpiece options maintain point and line combination flexibility for customized protocols across facial zones including periorbital areas served by the dedicated MF2 probe technology.
| Parameter | Specification |
|---|---|
| Model | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |