MF2 Eye Special Probe — Global Original Patent HIFU System
No reviews yetKey attributes
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
Similar products
Key attributes
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The TAIET system includes the MF2 global original patent probe, developed as a dedicated eye solution within the MPFU ultramicro pulse ultrasonic platform. This probe operates at 5.5MHz and applies lateral linear acoustic pulse and ring acoustic wave dual mode technology to address the delicate periorbital area. The ultra-thin probe design supports precise delivery of microsecond energy transmission to superficial lines, deeper creases, and under-eye concerns without epidermal damage or extended recovery periods. Practitioners can switch between point and MP modes on the same contact interface, adapting treatment density to individual tissue response around the eye contour, forehead, and neck zones where standard transducers lack suitable access or precision. The MF2 probe integrates with the broader T-1.5 to T-4.5 facial probe series, enabling multi-depth protocols that span from epidermal tone correction through to SMAS layer engagement. In combination with the flat handpiece and ring handpiece options, the system delivers customized full-layer programs that respect the thin, mobile nature of periorbital skin while contributing to overall facial contour coherence through collagen activation and fascial support.
| Parameter | Specification |
|---|---|
| Model | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Probe depth T-4.5 | 4.5 mm |
| Probe depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |