Equipment / TAIET
HIFU Eye Contour System with MF2 Patent Probe
No reviews yetKey attributes
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission mode
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
Similar products
Key attributes
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The TAIET system features the MF2 global original patent probe, the world's first 5.5 MHz eye-specific transducer developed for delicate periorbital applications. This ultra-thin probe employs unique Kolesi patent technology to address shallow fine lines, deeper expression lines, dark circles and under-eye concerns with precision energy delivery. The MF2 probe operates within the MPFU ultramicro pulse ultrasonic platform, enabling practitioners to switch between point and multipoint line modes at the same contact interface for customized eye-area protocols. TCP thermal condensation point technology in both normal and micropulse modes generates targeted thermal effects at the appropriate tissue depth while preserving surrounding structures. The pen-type circular 8 mm diameter handpiece supports ring-running optimization for continuous, seamless operation around the orbital region. Combined with the system's bidirectional energy switch and lateral linear acoustic pulse capabilities, the MF2 probe allows point, line and surface combination treatments tailored to individual eye-area anatomy and skin condition.
| Parameter | Specification |
|---|---|
| Model | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |