Dual-Mode HIFU System with Lateral Linear and Ring Acoustic Wave Output
No reviews yetKey attributes
- Technology
- MPFU
- Ultrasonic system
- Ultramicro pulse ultrasonic system
- Energy transmission mode
- microsecond energy transmission mode
- MF2 probe frequency
- 5.5 MHz
- Ring handpiece diameter
- 8 mm
- Normal mode points per shot
- 17 points
Similar products
Key attributes
| Technology | MPFU |
|---|---|
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The TAIET system combines lateral linear acoustic pulse and ring acoustic wave dual mode output within a single MPFU ultramicro pulse ultrasonic platform. A flat handpiece enables point and line combination treatment across skin layers, while a dedicated ring handpiece provides surface coverage operation for broader areas. Both modes share the same probe contact interface with free mode switching between normal TCP thermal condensation point and micropulse superposition configurations. The pen-type circular ring handpiece integrates micro transducer innovation technology for continuous annular energy delivery. This dual-path architecture supports full-layer protocols from superficial dermal activation through fascial layer targeting without epidermal damage. The system accommodates customized treatment plans through multimodal combination therapy, layering point patterns with multi-point line sequences for comprehensive coverage.
| Parameter | Specification |
|---|---|
| Model | TAIET |
| Technology | MPFU |
| Ultrasonic system | Ultramicro pulse ultrasonic system |
| Energy transmission mode | microsecond energy transmission mode |
| MF2 probe frequency | 5.5 MHz |
| Ring handpiece diameter | 8 mm |
| Normal mode points per shot | 17 points |
| MP mode points per shot | 417 points |
| Point duration | 1.111 seconds |
| Calibration return time | 0.5 seconds |
| MP mode duration | 0.416 seconds |
| Normal mode cycle time | 2.722 seconds |
| MP mode cycle time | 0.932 seconds |
| Speed improvement factor | 2.5 times |
| Treatment depth T-4.5 | 4.5 mm |
| Treatment depth B-4.5 | 4.5 mm |
| B-3.0 frequency | 7 MHz |
| B-4.5 frequency | 4 MHz |