Equipment / L10
L10 Multi-Mode CO2 Fractional Vaginal Laser for Aesthetic and Intimate Procedures
No reviews yetKey attributes
- Laser Wavelength
- 9.3–10.6 μm
- Far-Infrared Wavelength
- 10.6 μm
- Laser Power
- 60 W
- Operating Frequency
- 0–20 KHz
- RF Frequency
- 20 KHz
- Total Power
- 350 W
Similar products
Key attributes
| Laser Wavelength | 9.3–10.6 μm |
|---|---|
| Far-Infrared Wavelength | 10.6 μm |
| Laser Power | 60 W |
| Operating Frequency | 0–20 KHz |
| RF Frequency | 20 KHz |
| Total Power | 350 W |
| Spot Size | 2.5 ± 0.2 mm |
| Power Supply | 110V–230V |
| Product Size | 616 × 342 × 175 mm |
| Display Screen | 7-inch Color Touch Screen |
| Shell Material | Sheet Metal + Plastic |
| Color | Black + Dark Gray |
| Output Mode | TEM00 |
| Cooling System | Air Cooling + Water Cooling |
| Maximum Output Power | 30 W |
| CO2 Laser Wavelength | 10.6 μm |
| Power Cable Specification | 220V, 10A single-phase AC |
| Water Replacement Interval | once a month |
| Water Type | purified water or distilled water |
| Distance Adjustment Range | 0.1-2.6 nm |
| Duration Adjustment Range | 0.1-10 ms |
| OFF Time Adjustment Range | 1-1000 ms |
| On Time Adjustment Range | 1-1000 ms |
| Overlap Adjustment Range | 1-20th |
| Point Adjustment Range | 4-100 ms |
| Power Adjustment Range | 1-60 W |
| Pulse Width Adjustment Range | 5.0-995.0 ms |
| Rcan Line Number Adjustment Range | 0.1-10.0 J/cm² |
| Repeat Adjustment Range | 1-1000 ms |
| Row Adjustment Range | 1-10 |
| Shape Adjustment Range | 4.0x4.0 to 12.0x12.0 mm |
| Size Fixed Value | 10.0 mm |
| Working Mode Options | Single, Continuous, Pulse |
| Scan Mode Options | Sequential Mode, Random Mode, Split Mode |
| Temperature Range | 50-70 °C |
| Wavelength | 10,600 nm |
| Cannula Withdrawal Distance | 0.5 cm |
| Treatment Distance | approximately 5 CM |
| Internal Treatment Count | three |
| Articulated Arm Count | 6 |
| Screen Size | 7-inch |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The L10 CO2 fractional vaginal laser delivers four dedicated operating modes through a single platform: Fractional, Normal (Pulsed), Vulvae, and Gyane (Internal). Each mode is accessed directly from the touchscreen interface, allowing practitioners to move between skin resurfacing, external genital treatment, and internal vaginal procedures without changing devices. The Fractional and Pulsed modes address scars, pigmentation, stretch marks, and skin rejuvenation, while the Vulvae and Gyane modes focus on intimate aesthetic concerns including vaginal tightening, lubrication, and tissue nourishment. A 360-degree radial emission cannula supports internal treatment with controlled withdrawal intervals, and a fixed circular spot handles external genital and vaginal opening applications. The system combines air and water cooling for sustained operation, with monthly distilled water replacement maintaining thermal stability. A six-joint articulated arm with galvo head provides flexible positioning across all treatment areas, and footswitch activation with emergency stop protection supports safe clinical workflow.
| Parameter | Specification |
|---|---|
| Model | L10 |
| Laser Wavelength | 9.3–10.6 μm |
| Far-Infrared Wavelength | 10.6 μm |
| Laser Power | 60 W |
| Operating Frequency | 0–20 KHz |
| RF Frequency | 20 KHz |
| Total Power | 350 W |
| Spot Size | 2.5 ± 0.2 mm |
| Power Supply | 110V–230V |
| Product Size | 616 × 342 × 175 mm |
| Display Screen | 7-inch Color Touch Screen |
| Shell Material | Sheet Metal + Plastic |
| Color | Black + Dark Gray |
| Output Mode | TEM00 |
| Cooling System | Air Cooling + Water Cooling |
| Maximum Output Power | 30 W |
| CO2 Laser Wavelength | 10.6 μm |
| Power Cable Specification | 220V, 10A single-phase AC |
| Water Replacement Interval | once a month |
| Water Type | purified water or distilled water |
| Distance Adjustment Range | 0.1-2.6 nm |
| Duration Adjustment Range | 0.1-10 ms |
| OFF Time Adjustment Range | 1-1000 ms |
| On Time Adjustment Range | 1-1000 ms |
| Overlap Adjustment Range | 1-20th |
| Point Adjustment Range | 4-100 ms |
| Power Adjustment Range | 1-60 W |
| Pulse Width Adjustment Range | 5.0-995.0 ms |
| Rcan Line Number Adjustment Range | 0.1-10.0 J/cm² |
| Repeat Adjustment Range | 1-1000 ms |
| Row Adjustment Range | 1-10 |
| Shape Adjustment Range | 4.0x4.0 to 12.0x12.0 mm |
| Size Fixed Value | 10.0 mm |
| Working Mode Options | Single, Continuous, Pulse |
| Scan Mode Options | Sequential Mode, Random Mode, Split Mode |
| Temperature Range | 50-70 °C |
| Wavelength | 10,600 nm |
| Cannula Withdrawal Distance | 0.5 cm |
| Treatment Distance | approximately 5 CM |
| Internal Treatment Count | three |
| Articulated Arm Count | 6 |
| Screen Size | 7-inch |