Equipment / L10
L10 CO2 Fractional Vaginal Laser — Footswitch-Activated Safety System
No reviews yetKey attributes
- Laser Wavelength
- 9.3–10.6 μm
- Far-Infrared Wavelength
- 10.6 μm
- Laser Power
- 60 W
- Operating Frequency
- 0–20 KHz
- RF Frequency
- 20 KHz
- Total Power
- 350 W
Similar products
Key attributes
| Laser Wavelength | 9.3–10.6 μm |
|---|---|
| Far-Infrared Wavelength | 10.6 μm |
| Laser Power | 60 W |
| Operating Frequency | 0–20 KHz |
| RF Frequency | 20 KHz |
| Total Power | 350 W |
| Spot Size | 2.5 ± 0.2 mm |
| Power Supply | 110V–230V |
| Product Size | 616 × 342 × 175 mm |
| Display Screen | 7-inch Color Touch Screen |
| Shell Material | Sheet Metal + Plastic |
| Color | Black + Dark Gray |
| Output Mode | TEM00 |
| Cooling System | Air Cooling + Water Cooling |
| Maximum Output Power | 30 W |
| CO2 Laser Wavelength | 10.6 μm |
| Power Cable Specification | 220V, 10A single-phase AC |
| Water Replacement Interval | once a month |
| Water Type | purified water or distilled water |
| Distance Adjustment Range | 0.1-2.6 nm |
| Duration Adjustment Range | 0.1-10 ms |
| OFF Time Adjustment Range | 1-1000 ms |
| On Time Adjustment Range | 1-1000 ms |
| Overlap Adjustment Range | 1-20th |
| Point Adjustment Range | 4-100 ms |
| Power Adjustment Range | 1-60 W |
| Pulse Width Adjustment Range | 5.0-995.0 ms |
| Rcan Line Number Adjustment Range | 0.1-10.0 J/cm² |
| Repeat Adjustment Range | 1-1000 ms |
| Row Adjustment Range | 1-10 |
| Shape Adjustment Range | 4.0x4.0 to 12.0x12.0 mm |
| Size Fixed Value | 10.0 mm |
| Working Mode Options | Single, Continuous, Pulse |
| Scan Mode Options | Sequential Mode, Random Mode, Split Mode |
| Temperature Range | 50-70 °C |
| Wavelength | 10,600 nm |
| Cannula Withdrawal Distance | 0.5 cm |
| Treatment Distance | approximately 5 CM |
| Internal Treatment Count | three |
| Articulated Arm Count | 6 |
| Screen Size | 7-inch |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The L10 CO2 fractional vaginal laser is built around operator-controlled safety, combining footswitch activation with an emergency stop switch for immediate shutdown capability. The system runs on standard single-phase AC power, making it straightforward to integrate into clinical environments without specialized electrical infrastructure. Every treatment begins with intentional foot pedal engagement, ensuring the laser emits only when the operator deliberately commands it. The emergency stop provides an additional hardware-level safeguard for both practitioner and patient confidence. This control architecture supports four distinct operating modes: Fractional, Normal pulsed delivery, external Vulvae treatment, and internal Gyane application. The 7-inch color touchscreen interface allows English and Chinese language switching, while the 6-joint articulated arm with galvo head delivers precise beam positioning across all protocols. Dual air and water cooling maintains thermal stability during extended use, with monthly distilled water replacement as routine upkeep. The 360-degree radial emission cannula enables comprehensive internal vaginal coverage with measured withdrawal intervals, while a fixed circular spot configuration addresses external genital and vaginal opening applications. Sheet metal and plastic housing in black and dark gray finish provides durable, compact construction suitable for professional aesthetic and gynecological settings.
| Parameter | Specification |
|---|---|
| Model | L10 |
| Laser Wavelength | 9.3–10.6 μm |
| Far-Infrared Wavelength | 10.6 μm |
| Laser Power | 60 W |
| Operating Frequency | 0–20 KHz |
| RF Frequency | 20 KHz |
| Total Power | 350 W |
| Spot Size | 2.5 ± 0.2 mm |
| Power Supply | 110V–230V |
| Product Size | 616 × 342 × 175 mm |
| Display Screen | 7-inch Color Touch Screen |
| Shell Material | Sheet Metal + Plastic |
| Color | Black + Dark Gray |
| Output Mode | TEM00 |
| Cooling System | Air Cooling + Water Cooling |
| Maximum Output Power | 30 W |
| CO2 Laser Wavelength | 10.6 μm |
| Power Cable Specification | 220V, 10A single-phase AC |
| Water Replacement Interval | once a month |
| Water Type | purified water or distilled water |
| Distance Adjustment Range | 0.1-2.6 nm |
| Duration Adjustment Range | 0.1-10 ms |
| OFF Time Adjustment Range | 1-1000 ms |
| On Time Adjustment Range | 1-1000 ms |
| Overlap Adjustment Range | 1-20th |
| Point Adjustment Range | 4-100 ms |
| Power Adjustment Range | 1-60 W |
| Pulse Width Adjustment Range | 5.0-995.0 ms |
| Rcan Line Number Adjustment Range | 0.1-10.0 J/cm² |
| Repeat Adjustment Range | 1-1000 ms |
| Row Adjustment Range | 1-10 |
| Shape Adjustment Range | 4.0x4.0 to 12.0x12.0 mm |
| Size Fixed Value | 10.0 mm |
| Working Mode Options | Single, Continuous, Pulse |
| Scan Mode Options | Sequential Mode, Random Mode, Split Mode |
| Temperature Range | 50-70 °C |
| Wavelength | 10,600 nm |
| Cannula Withdrawal Distance | 0.5 cm |
| Treatment Distance | approximately 5 CM |
| Internal Treatment Count | three |
| Articulated Arm Count | 6 |
| Screen Size | 7-inch |