Equipment / L10
CO2 Fractional Vaginal Laser L10 — Compact Clinical System
No reviews yetKey attributes
- Laser Wavelength
- 9.3–10.6 μm
- Far-Infrared Wavelength
- 10.6 μm
- Laser Power
- 60 W
- Operating Frequency
- 0–20 KHz
- RF Frequency
- 20 KHz
- Total Power
- 350 W
Similar products
Key attributes
| Laser Wavelength | 9.3–10.6 μm |
|---|---|
| Far-Infrared Wavelength | 10.6 μm |
| Laser Power | 60 W |
| Operating Frequency | 0–20 KHz |
| RF Frequency | 20 KHz |
| Total Power | 350 W |
| Spot Size | 2.5 ± 0.2 mm |
| Power Supply | 110V–230V |
| Product Size | 616 × 342 × 175 mm |
| Display Screen | 7-inch Color Touch Screen |
| Shell Material | Sheet Metal + Plastic |
| Color | Black + Dark Gray |
| Output Mode | TEM00 |
| Cooling System | Air Cooling + Water Cooling |
| Maximum Output Power | 30 W |
| CO2 Laser Wavelength | 10.6 μm |
| Power Cable Specification | 220V, 10A single-phase AC |
| Water Replacement Interval | once a month |
| Water Type | purified water or distilled water |
| Distance Adjustment Range | 0.1-2.6 nm |
| Duration Adjustment Range | 0.1-10 ms |
| OFF Time Adjustment Range | 1-1000 ms |
| On Time Adjustment Range | 1-1000 ms |
| Overlap Adjustment Range | 1-20th |
| Point Adjustment Range | 4-100 ms |
| Power Adjustment Range | 1-60 W |
| Pulse Width Adjustment Range | 5.0-995.0 ms |
| Rcan Line Number Adjustment Range | 0.1-10.0 J/cm² |
| Repeat Adjustment Range | 1-1000 ms |
| Row Adjustment Range | 1-10 |
| Shape Adjustment Range | 4.0x4.0 to 12.0x12.0 mm |
| Size Fixed Value | 10.0 mm |
| Working Mode Options | Single, Continuous, Pulse |
| Scan Mode Options | Sequential Mode, Random Mode, Split Mode |
| Temperature Range | 50-70 °C |
| Wavelength | 10,600 nm |
| Cannula Withdrawal Distance | 0.5 cm |
| Treatment Distance | approximately 5 CM |
| Internal Treatment Count | three |
| Articulated Arm Count | 6 |
| Screen Size | 7-inch |
Ratings & reviews
No product reviews have been published.
No store reviews have been published.
Supplier
Product description
The L10 CO2 fractional vaginal laser delivers intimate rejuvenation and skin resurfacing in a compact, desk-friendly unit. Its sheet metal and plastic shell in black and dark gray houses a complete clinical workstation measuring just over six hundred millimeters in width, making it suitable for practices with limited floor space. The system supports fractional, pulsed, vulvar, and internal gynecological modes through a touchscreen interface with English and Chinese switching, operated via footswitch with emergency stop protection. Dual air and water cooling maintains stable performance during extended use, with monthly distilled water replacement keeping maintenance predictable. A six-joint articulated arm with galvo head provides flexible positioning, while the 360-degree radial emission cannula enables comprehensive internal vaginal treatment with measured withdrawal intervals. External genital applications use a fixed circular spot size at a controlled distance from the treatment area, allowing practitioners to address both intimate tightening and surface skin concerns with one integrated platform.
| Parameter | Specification |
|---|---|
| Model | L10 |
| Laser Wavelength | 9.3–10.6 μm |
| Far-Infrared Wavelength | 10.6 μm |
| Laser Power | 60 W |
| Operating Frequency | 0–20 KHz |
| RF Frequency | 20 KHz |
| Total Power | 350 W |
| Spot Size | 2.5 ± 0.2 mm |
| Power Supply | 110V–230V |
| Product Size | 616 × 342 × 175 mm |
| Display Screen | 7-inch Color Touch Screen |
| Shell Material | Sheet Metal + Plastic |
| Color | Black + Dark Gray |
| Output Mode | TEM00 |
| Cooling System | Air Cooling + Water Cooling |
| Maximum Output Power | 30 W |
| CO2 Laser Wavelength | 10.6 μm |
| Power Cable Specification | 220V, 10A single-phase AC |
| Water Replacement Interval | once a month |
| Water Type | purified water or distilled water |
| Distance Adjustment Range | 0.1-2.6 nm |
| Duration Adjustment Range | 0.1-10 ms |
| OFF Time Adjustment Range | 1-1000 ms |
| On Time Adjustment Range | 1-1000 ms |
| Overlap Adjustment Range | 1-20th |
| Point Adjustment Range | 4-100 ms |
| Power Adjustment Range | 1-60 W |
| Pulse Width Adjustment Range | 5.0-995.0 ms |
| Rcan Line Number Adjustment Range | 0.1-10.0 J/cm² |
| Repeat Adjustment Range | 1-1000 ms |
| Row Adjustment Range | 1-10 |
| Shape Adjustment Range | 4.0x4.0 to 12.0x12.0 mm |
| Size Fixed Value | 10.0 mm |
| Working Mode Options | Single, Continuous, Pulse |
| Scan Mode Options | Sequential Mode, Random Mode, Split Mode |
| Temperature Range | 50-70 °C |
| Wavelength | 10,600 nm |
| Cannula Withdrawal Distance | 0.5 cm |
| Treatment Distance | approximately 5 CM |
| Internal Treatment Count | three |
| Articulated Arm Count | 6 |
| Screen Size | 7-inch |